PRODUCTS
U1-Industrial Acoustic Imager (Gas Leak Version)
U1-Industrial Acoustic Imager (Gas Leak Version)
U1-Industrial Acoustic Imager (Gas Leak Version)
U1-Industrial Acoustic Imager (Gas Leak Version)
U1-Industrial Acoustic Imager (Gas Leak Version)
U1-Industrial Acoustic Imager (Gas Leak Version)
U1-Industrial Acoustic Imager (Gas Leak Version)
U1-Industrial Acoustic Imager (Gas Leak Version)
U1-Industrial Acoustic Imager (Gas Leak Version)
U1-Industrial Acoustic Imager (Gas Leak Version)
U1-Industrial Acoustic Imager (Gas Leak Version)
U1-Industrial Acoustic Imager (Gas Leak Version)
U1-Industrial Acoustic Imager (Gas Leak Version)
+
  • U1-Industrial Acoustic Imager (Gas Leak Version)
  • U1-Industrial Acoustic Imager (Gas Leak Version)
  • U1-Industrial Acoustic Imager (Gas Leak Version)
  • U1-Industrial Acoustic Imager (Gas Leak Version)
  • U1-Industrial Acoustic Imager (Gas Leak Version)
  • U1-Industrial Acoustic Imager (Gas Leak Version)
  • U1-Industrial Acoustic Imager (Gas Leak Version)
  • U1-Industrial Acoustic Imager (Gas Leak Version)
  • U1-Industrial Acoustic Imager (Gas Leak Version)
  • U1-Industrial Acoustic Imager (Gas Leak Version)
  • U1-Industrial Acoustic Imager (Gas Leak Version)
  • U1-Industrial Acoustic Imager (Gas Leak Version)
  • U1-Industrial Acoustic Imager (Gas Leak Version)

U1-Industrial Acoustic Imager (Gas Leak Version)

The U1 Industrial Acoustic Imager is a handheld industrial acoustic imager that supports ultrasonic frequencies. The instrument uses microphone array beamforming technology to acquire sound source distribution data, and is equipped with a high-definition camera to collect video images in real time. By integrating the sound source distribution data with the video images, the changing sound source is dynamically displayed on the screen. The U1 Industrial Acoustic Imager can help you quickly detect possible leaks in air, gas, and vacuum in noisy industrial environments; and it can store the detected images and videos for playback or report generation through image or video capture functions.

Key words:

akoestische camera

Sound Source Localization

Classification:

Product Characteristics

  • MEMS Microphone

    132 digital MEMS microphones; frequency range 1K~100kHz
     
  • Capacitive Touchscreen

    8-inch IPS touchscreen with full viewing angle and high brightness, resolution 1280*800
  • Working Distance

    Working distance 0.5 meters to 120 meters
  • Adjustable Focus

    Camera with adjustable zoom, real-time frame rate up to 25fps
  • Multi-Source

    Supports multi-source mode, each source can display real-time amplitude
  • Monitorable

    Supports headphone monitoring function, allowing real-time monitoring of audio signals;
  • Fast Charging Protocol

    Type-C port charging, supports fast charging protocols such as PD, up to 60W
     
  • Other

    Auxiliary lighting;

 

Product Parameters

I. Introduction to Intelligent Acoustic Imager

A container is filled with gas. When the internal pressure is greater than the external pressure, due to the large pressure difference, gas will rush out from any leaks in the container. When the leak size is small and the Reynolds number is high, the escaping gas will form turbulence, and the turbulence will generate sound waves of a certain frequency near the leak. The frequency of the sound wave vibration is related to the size of the leak. For larger leaks, the gas leak sound is audible to the human ear. For very small leaks, where the sound wave frequency is greater than 20KHz, it is inaudible to the human ear, but it can still propagate in the air and is called airborne ultrasound. An intelligent acoustic imager is an intuitive and easy-to-use tool that can identify the sound frequencies of gas leaks. Using an array of 128 highly sensitive digital microphones, it converts the collected sound into a visible light image, displaying it on the screen as a graph to help teams detect leaks early.

 

II. Introduction to Gas Leaks

At industrial gas production or use sites, the crisscrossing of gas pipelines, the concentration of pipe joints and valves, combined with weather conditions, human damage, and natural corrosion, make gas pipelines prone to leaks. Because the sound amplitude of gas leaks is difficult for humans to perceive, when a gas leak occurs, inspectors fail to make timely repairs, leading to untimely maintenance, which causes huge economic losses and the risk of gas explosions.

 

III. Losses Caused by Gas Leaks

 

IV. Comparison of Traditional Methods and Intelligent Acoustic Imagers

 

 

V. Test Site

 

 

VI. Test Report Analysis

VII. Frequently Asked Questions

1. What types of systems can the intelligent acoustic imager detect?

Supports most gas detection.

2. What is the detectable leakage range?

The fault point is visible, greater than 0.2mpa.

3. Detection effect under environmental interference?

Uses ultrasonic frequency band detection to avoid audible range interference noise in the environment.

The spatial filtering characteristics of the equipment (algorithm) avoid interference.

During the detection operation, adjust the angle and distance to avoid interference.

Related products

Hardware products

MDVRS

Al Processing Units

Passenger Information System

Displays

Smart Payment

Other

Leave Us A Message Now


Attention: We Can Produce Customized Products. If Necessary, Please Make Sure To Accurately Fill In The Information And Maintain Smooth Communication. We Will Contact You As Soon As Possible.